Our green THHN/THWN-2/T90 nylon-jacketed wire meets UL83 and CSA22.2 NO.75 certifications, ensuring maximum safety with heat resistance, moisture protection, and long-lasting nylon insulation. The green color subtly emphasizes safety and eco-consciousness, making it ideal for grounding, bonding, or sustainable applications where color-specific identification supports hazard prevention.
Specification
Conductor | Insulation Thickness (mils) |
Jacket Thickness (mils) |
Nominal O.D. (mils) |
Approx. Net Wt. Per 1000′ (lbs.) |
Allowable Ampacities+ | |||
---|---|---|---|---|---|---|---|---|
60°C | 75°C | 90°C | ||||||
14* | 1 | 15 | 4 | 102 | 15 | 15 | 15 | 15 |
12* | 1 | 15 | 4 | 119 | 23 | 20 | 20 | 20 |
10* | 1 | 20 | 4 | 150 | 36 | 30 | 30 | 30 |
14* | 19 | 15 | 4 | 109 | 16 | 15 | 15 | 15 |
12* | 19 | 15 | 4 | 128 | 24 | 20 | 20 | 20 |
10* | 19 | 20 | 4 | 161 | 38 | 30 | 30 | 30 |
8 | 19 | 30 | 5 | 213 | 63 | 40 | 50 | 55 |
6 | 19 | 30 | 5 | 249 | 95 | 55 | 65 | 75 |
4 | 19 | 40 | 6 | 318 | 152 | 70 | 85 | 100 |
3 | 19 | 40 | 6 | 346 | 189 | 85 | 100 | 115 |
2 | 19 | 40 | 6 | 378 | 234 | 95 | 115 | 130 |
1 | 19 | 50 | 7 | 435 | 299 | 110 | 130 | 145 |
1/0 | 19 | 50 | 7 | 474 | 372 | 125 | 150 | 170 |
2/0 | 19 | 50 | 7 | 518 | 462 | 145 | 175 | 195 |
3/0 | 19 | 50 | 7 | 568 | 575 | 165 | 200 | 225 |
4/0 | 19 | 50 | 7 | 624 | 718 | 195 | 230 | 260 |
250 | 37 | 60 | 8 | 694 | 851 | 215 | 255 | 290 |
300 | 37 | 60 | 8 | 747 | 1012 | 240 | 285 | 320 |
350 | 37 | 60 | 8 | 797 | 1174 | 260 | 310 | 350 |
400 | 37 | 60 | 8 | 842 | 1334 | 280 | 335 | 380 |
500 | 37 | 60 | 8 | 926 | 1655 | 320 | 380 | 430 |
600 | 61 | 70 | 9 | 1024 | 1987 | 350 | 420 | 475 |
750 | 61 | 70 | 9 | 1126 | 2464 | 400 | 475 | 535 |
1000 | 61 | 70 | 9 | 1275 | 3257 | 455 | 545 | 615 |
* Sizes 14, 12, and 10 AWG are available with Technology only in Barrel configurations. Standard put ups vary from the ones shown on this chart for standard 14-10 AWG THHN
+Allowable ampacities shown are for general use as specified by the 2014 Edition of the National Electrical Code Sections 310.15 and 240.4(D)
Unless the equipment is marked for use at higher temperatures the conductor shall be limited to the following per NEC 110.14(C):
- 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 – 1 AWG conductors
- 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG
- 90°C – THHN dry locations and THWN-2 wet or dry locations for ampacity adjustment purposes using NEC section 310.15
Application
- Grounding and bonding systems in electrical panels or equipment enclosures, using green wiring for enhanced safety and compliance in industrial setups.
- Renewable energy installations, like solar panels and wind turbines, where color-coding aids in sustainable power management.
- Safety-critical circuits in public infrastructure, such as schools or hospitals, for reliable connection in life-saving devices.
- Control wiring for green-certified buildings, facilitating easy identification in environmental monitoring systems.
JZD Factory
JZD Wire & Cable has been established for over 25 years, We are manufacturing and supplying quality electrical cables to America, Canada, European countries, Philippines. Australia, South American countries, South Africa, ect. JZD Wire & Cable makes customized cables for a complete range in this industry, including single and multi-cores cables, such as : Solar Cable, THHN Nylon Cable, Building wire, Flat TPS Cable, AC Cable, MC Cable, NM-B, NMD90, Fire rated cable, Silicone Cable, ect. High quality products that JZD provided have been taken part in lots of buildings and projects all over the world. Like airports, schools, hospitals, factories, ect.