THHN Cable for Data Centers

Specification
| Conductor | Insulation Thickness (mils) |
Jacket Thickness (mils) |
Nominal O.D. (mils) |
Approx. Net Wt. Per 1000′ (lbs.) |
Allowable Ampacities+ | |||
|---|---|---|---|---|---|---|---|---|
| 60°C | 75°C | 90°C | ||||||
| 14* | 1 | 15 | 4 | 102 | 15 | 15 | 15 | 15 |
| 12* | 1 | 15 | 4 | 119 | 23 | 20 | 20 | 20 |
| 10* | 1 | 20 | 4 | 150 | 36 | 30 | 30 | 30 |
| 14* | 19 | 15 | 4 | 109 | 16 | 15 | 15 | 15 |
| 12* | 19 | 15 | 4 | 128 | 24 | 20 | 20 | 20 |
| 10* | 19 | 20 | 4 | 161 | 38 | 30 | 30 | 30 |
| 8 | 19 | 30 | 5 | 213 | 63 | 40 | 50 | 55 |
| 6 | 19 | 30 | 5 | 249 | 95 | 55 | 65 | 75 |
| 4 | 19 | 40 | 6 | 318 | 152 | 70 | 85 | 100 |
| 3 | 19 | 40 | 6 | 346 | 189 | 85 | 100 | 115 |
| 2 | 19 | 40 | 6 | 378 | 234 | 95 | 115 | 130 |
| 1 | 19 | 50 | 7 | 435 | 299 | 110 | 130 | 145 |
| 1/0 | 19 | 50 | 7 | 474 | 372 | 125 | 150 | 170 |
| 2/0 | 19 | 50 | 7 | 518 | 462 | 145 | 175 | 195 |
| 3/0 | 19 | 50 | 7 | 568 | 575 | 165 | 200 | 225 |
| 4/0 | 19 | 50 | 7 | 624 | 718 | 195 | 230 | 260 |
| 250 | 37 | 60 | 8 | 694 | 851 | 215 | 255 | 290 |
| 300 | 37 | 60 | 8 | 747 | 1012 | 240 | 285 | 320 |
| 350 | 37 | 60 | 8 | 797 | 1174 | 260 | 310 | 350 |
| 400 | 37 | 60 | 8 | 842 | 1334 | 280 | 335 | 380 |
| 500 | 37 | 60 | 8 | 926 | 1655 | 320 | 380 | 430 |
| 600 | 61 | 70 | 9 | 1024 | 1987 | 350 | 420 | 475 |
| 750 | 61 | 70 | 9 | 1126 | 2464 | 400 | 475 | 535 |
| 1000 | 61 | 70 | 9 | 1275 | 3257 | 455 | 545 | 615 |
* Sizes 14, 12, and 10 AWG are available with Technology only in Barrel configurations. Standard put ups vary from the ones shown on this chart for standard 14-10 AWG THHN
+Allowable ampacities shown are for general use as specified by the 2014 Edition of the National Electrical Code Sections 310.15 and 240.4(D)
Unless the equipment is marked for use at higher temperatures the conductor shall be limited to the following per NEC 110.14(C):
- 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 – 1 AWG conductors
- 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG
- 90°C – THHN dry locations and THWN-2 wet or dry locations for ampacity adjustment purposes using NEC section 310.15
Primary Application: Data Centers
Data centers require wiring solutions that guarantee maximum uptime, safety, and efficiency. Our THHN cable is ideally suited for the robust power distribution needs of modern data center environments.
- Power Feeds & Busway Drops: Perfect for connecting main power panels to busways (power distribution units/PDUs) and for final circuit drops to server racks and cabinets, providing stable and uninterrupted power delivery.
- HVAC & Cooling Systems: Essential for wiring critical cooling infrastructure, including CRAC (Computer Room Air Conditioning) units and fan systems, where cables may be exposed to higher ambient temperatures.
- Support Infrastructure: Reliably powers ancillary systems such as lighting, security systems, and fire alarm panels within the data center facility.
1. Outdoor Conduit Installations
• Solar Farms: UV-stable wiring for combiner boxes and tracker systems
• Parking Lot Lighting: Conduit wiring for pole-mounted fixtures
• Bridge/Tunnel Electrification: Exposed conduit runs in coastal/high-UV zones
2. Industrial Exposed Sites
• Oil & Gas Plants: Conduits in refinery pipe racks and drilling platforms
• Water Treatment Facilities: Chemical-resistant UV wiring for control conduits
3. Infrastructure & Municipal
• Traffic Signal Systems: Wiring for signal cabinets and overhead mast arms
• Airfield Ground Lighting: Runways/taxiways in high-UV geographies
4. Renewable Energy Integration
• Wind turbine conduit systems
• EV charging station raceways

JZD Factory
JZD Wire & Cable has been established for over 25 years, We are manufacturing and supplying quality electrical cables to America, Canada, European countries, Philippines. Australia, South American countries, South Africa, ect. JZD Wire & Cable makes customized cables for a complete range in this industry, including single and multi-cores cables, such as : Solar Cable, THHN Nylon Cable, Building wire, Flat TPS Cable, AC Cable, MC Cable, NM-B, NMD90, Fire rated cable, Silicone Cable, ect. High quality products that JZD provided have been taken part in lots of buildings and projects all over the world. Like airports, schools, hospitals, factories, ect.